1 Inverter Installation ManualSolar-Log™ EN
10 67 Riello ������������������������������������������������������������������������������������������������������������������������������19067�1 Ri
100EvocoEvoco29 Evoco29�1 EvocoEasy Installation Termination Addressing InterfaceNoYesYesRS485Overview•Integrated interface•Where to connect: Betwe
101EvocoEvocoProcedure1. Insert the round plug into any round socket on inverter 1.2. Insert the other end of the cable into any round socket on inv
102FroniusFronius with ComCard30 Fronius30�1 Fronius with ComCardEasy Installation Termination Addressing InterfaceYesConnection plugBridge 4-3 + 5-6
103FroniusFronius with ComCardProcedure1. If you are making the cable yourself, connect the wires as shown in the following diagram: Solar-Log™ termi
104FroniusFronius Symo and Galvo models30�2 Fronius Symo and Galvo modelsFor the Symo and Galvo series, Fronius offers two different inverters:•Symo
105FroniusFronius RL30�3 Fronius RLEasy Installation Termination Addressing InterfaceYesJumperYesRS485Overview•Integrated interface•Where to connec
106GefranGefran31 Gefran31�1 GefranEasy Installation Termination Addressing InterfaceNo Switch YesRS485 Overview•Integrated interface (two independ
107GefranGefranProcedure1. Open the inverter as shown in the inverter’s instructions.2. If you are making the cable yourself, connect the wires as s
108GefranGefranConnect the inverters to each other•Where to connect: Terminal strip inside the inverter•2-pin wiringProcedure1. Open the inverter a
109General Electric inverters (GE)General Electric inverters (GE)32 General Electric inverters (GE)32�1 General Electric inverters (GE)Easy Installat
11 76 SMA �������������������������������������������������������������������������������������������������������������������������������22076�1 Over
110GESOLARGESOLAR33 GESOLAR33�1 GESOLAREasy Installation Termination Addressing InterfaceNo Yes NoRS485Overview•Integrated interface•Where to conne
111GESOLARGESOLARConnect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: RJ45 sockets on the outside of th
112GinlongGinlong34 Ginlong34�1 GinlongEasy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated interface•Where to conn
113GinlongGinlongAllocate communication address•Recommendation: Continuous numbering starting with 1.•Default settings on the inverter: Communicatio
114GMDEGMDE35 GMDE35�1 GMDEEasy Installation Termination Addressing InterfaceNo Yes NoRS485Overview•Integrated RS485 interface•8-pin cable for the
115GMDEGMDEConnect the inverters to each other•Connect using a network cable (patch cable).•Where to connect: RJ45 socket on the outside of the inve
116GoodWeGoodWe36 GoodWe36�1 GoodWeEasy Installation Termination Addressing InterfaceNo Yes NoRS422Overview•Integrated RS422 interface•8-pin cable
117GoodWeGoodWeConnect the inverters to each other•Connect using a network cable (patch cable).•Where to connect: RJ45 socket on the outside of the
118GrowattGrowatt37 Growatt37�1 GrowattEasy Installation Termination Addressing InterfaceNo - YesRS485Overview•Integrated interface•Where to connec
119GrowattGrowattAllocate communication address•Recommendation: Continuous numbering starting with 1.•Address range: 1 - 125 •Setting: Using the in
12 84 Sungrow ����������������������������������������������������������������������������������������������������������������������26084�1 Sungrow �
120GTecGTec38 GTe c38�1 GTecEasy Installation Termination Addressing InterfaceNo Yes NoRS422Overview•Interface not integrated; Retrofit RS485 interf
121GTecGTecProcedure1. Open the inverter as shown in the inverter's instructions.2. Pull the free wires through the wire opening in the inverte
122Helios SystemsHelios Systems39 Helios Systems39�1 Helios SystemsEasy Installation Termination Addressing InterfaceNo Yes YesRS485String Inverter H
123Helios SystemsHelios SystemsConnect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: 2 RJ45 sockets Proc
124HuaweiHuawei40 Huawei40�1 HuaweiEasy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated interface•Where to connect:
125HuaweiHuaweiConnect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: 2 RJ45 sockets Procedure•Open the
126HyundaiHyundai HPC-050HT-E and HPC-100HT-E41 Hyundai41�1 Hyundai HPC-050HT-E and HPC-100HT-EEasy Installation Termination Addressing InterfaceNo Y
127HyundaiHyundai HPC-050HT-E and HPC-100HT-EConnect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: RJ45
128HyundaiHyundai HPC-250HT-E41�2 Hyundai HPC-250HT-EEasy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated interface•
129HyundaiHyundai HPC-250HT-EProcedure1. Connect terminal D1+/TxD1+ on inverter 1 to terminal D1+/TxD1+ on inverter 2.2. Connect terminal D1–/TxD1–
13 94 Valenia ������������������������������������������������������������������������������������������������������������������������� 28594�1 Valen
130IngeteamIngeteam42 Ingeteam42�1 IngeteamEasy Installation Termination Addressing InterfaceNoJumper P3YesRS485Overview•Interface not integrated; R
131IngeteamIngeteamConnect the inverters to each other•Connect using a 3 wire, shielded data cable•Where to connect: Terminal strip inside the inver
132KacoKaco - Powador43 Kaco43�1 Kaco - PowadorEasy Installation Termination Addressing InterfaceYesYesYesRS485Overview•Integrated interface•Where
133KacoKaco - PowadorConnect the inverters to each other•Connect using a 2 wire, shielded data cable•Where to connect: Terminal strip inside the inv
134KacoKaco – PVI Blue Planet43�2 Kaco – PVI Blue PlanetEasy Installation Termination Addressing InterfaceYesSwitchYesRS485Overview•The Solar-Log™ o
135KacoKaco – PVI Blue PlanetProcedure1. Open the inverter as shown in the inverter's instructions.2. Connect the data cable to the free termin
136KLNEKLNE (Solartec and Sunteams)44 KLNE44�1 KLNE (Solartec and Sunteams)Easy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•
137KLNEKLNE (Solartec and Sunteams)Solar-Log™ terminal strip connector X4 socket inverterTerminal PIN ► 14 - Data+ ► 42 - Data-3. Connect the Solar-L
138Kostal and Solar-FabrikKostal Pico and Solar-Fabrik Inverter Convert T (RS485)45 Kostal and Solar-Fabrik45�1 Kostal Pico and Solar-Fabrik Inverter
139Kostal and Solar-FabrikKostal Pico and Solar-Fabrik Inverter Convert T (RS485)Procedure1. Open the inverter as shown in the inverter's instru
14 104 Appendix ��������������������������������������������������������������������������������������������������������������������308104�1 SMA mix
140Kostal and Solar-FabrikKostal Ethernet Version45�2 Kostal Ethernet VersionEasy Installation Termination Addressing InterfaceNo No YesLANOverview•
141Kostal and Solar-FabrikKostal Ethernet VersionNote Each inverter must be accessible through the network individually.It is thereby necessary to ac
142KstarKstar Multitracker46 Kstar46�1 Kstar MultitrackerEasy Installation Termination Addressing InterfaceNoDIP switchYesRS485Select “Kstar” during
143KstarKstar MultitrackerProcedure1. If you are fabricating the cable yourself, connect the wires as shown in the following diagram.Solar-Log™ termi
144KstarKstar Singletracker46�2 Kstar SingletrackerEasy Installation Termination Addressing InterfaceNoDIP switchYesRS485Select “Kstar SM” during the
145KstarKstar SingletrackerConnect the inverters to each other•Connect using a network cable (patch cable) (No Crossover cable)•Where to connect: RJ
146Kyocera Inverter/Battery SystemKyocera Inverter/Battery System47 Kyocera Inverter/Battery System47�1 Kyocera Inverter/Battery SystemEasy Installat
147Kyocera Inverter/Battery SystemKyocera Inverter/Battery SystemAllocate communication address:•Procedure: According to the manufacturer‘s manual.If
148Lufft - PyranometerLufft - Pyranometer48 Lut - Pyranometer48�1 Lut - PyranometerEasy Installation Termination Addressing InterfaceNo - No*RS485S
149MastervoltMastervolt (RS485)49 Mastervolt49�1 Mastervolt (RS485)Easy Installation Termination Addressing InterfaceYesYesNoRS485Overview•Integrate
15ConnectionsSolar-Log™ RS485/422 B connection assignments (6 pin)1 Connections1�1 Solar-Log™ RS485/422 B connection assignments (6 pin)The RS485/42
150MastervoltMastervolt (RS485)CautionRisk of damage to the unit! The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45 so
151MitsubishiMitsubishi with RS485 interface50 Mitsubishi50�1 Mitsubishi with RS485 interfaceEasy Installation Termination Addressing InterfaceNoSwit
152MitsubishiMitsubishi with RS485 interfaceProcedure1. Unscrew the front plate of the inverter as shown in the inverter's instructions.2. Inse
153MotechMotech (RS485)51 Motech51�1 Motech (RS485)Easy Installation Termination Addressing InterfaceNo Yes NoRS485Overview•Integrated interface•W
154MotechMotech (RS485)Connect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: RJ45 sockets on the outside
155OelmaierOelmaier52 Oelmaier52�1 OelmaierEasy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated interface•Where to
156OelmaierOelmaierProcedure1. Open the inverter as shown in the inverter's instructions.2. If you are making the cable yourself, connect the w
157OmnikOmnik53 Omnik53�1 OmnikEasy Installation Termination Addressing InterfaceNoNoAutomaticRS422Overview•Integrated interface•Where to connect:
158OmnikOmnikProcedure1. Connect the wires for the cable connection as shown in the following diagram.Solar-Log™ terminal strip connector RJ45 invert
159OmronOmron54 Omron54�1 OmronEasy Installation Termination Addressing InterfaceNo Bridge 9 -> 10 YesRS485Overview•Integrated interface•Where t
16ConnectionsRJ451�2 RJ45Some inverter manufacturers use RJ45 jacks on their units. The pin assignments are manufacturer-specific. Connect the RS485/
160OmronOmronProcedure1. Open the inverter as shown in the inverter's instructions.Inverter n Inverter n+1Terminal strip TB401 Terminal strip TB
161PairanPairan55 Pairan55�1 PairanEasy Installation Termination Addressing InterfaceNo Jumper NoRS485Overview•Integrated interface•Where to connec
162PairanPairanConnect the inverters to each other•Connect using a 2 wire, shielded data cable•Where to connect: Round socket on inverterProcedure1.
163PhoenixtecPhoenixtec56 Phoenixtec56�1 PhoenixtecEasy Installation Termination Addressing InterfaceYesYesNoRS422Selectable under SunvilleOverview•
164PhoenixtecPhoenixtecProcedure1. Open the inverter as shown in the inverter‘s instructions.2. Pull the free wires through the wire opening in the
165PhonosolarPhonoCube 7.2 (Battery Hybrid System)57 Phonosolar57�1 PhonoCube 7�2 (Battery Hybrid System)Easy Installation Termination Addressing Int
166PhonosolarPhonoCube 7.2 (Battery Hybrid System)Procedure1. Unscrew the cover according to the PhoneCube instructions.2. If you are fabricating th
167Platinum (formerly Diehl Ako)Platinum with RS485 interface58 Platinum (formerly Diehl Ako)58�1 Platinum with RS485 interfaceEasy Installation Term
168Platinum (formerly Diehl Ako)Platinum with RS485 interfaceConnect the inverters to each other•Connect using a network cable (patch cable)•Where t
169Platinum (formerly Diehl Ako)Platinum H58�2 Platinum HEasy Installation Termination Addressing InterfaceNoYesYesRS485Overview•Integrated interfac
17ConnectionsRJ11 Configuration1�3 RJ11 ConfigurationSome inverter manufacturers use RJ11 jacks on their units.The pin assignments are manufacturer-sp
170Platinum (formerly Diehl Ako)Platinum HOther configurations•Activate the RS485 interface Using the inverter operating display.Note Pay particular
171PowercomPowercom59 Powercom59�1 PowercomEasy Installation Termination Addressing InterfaceNoSwitchYesRS485Overview•Interface not integrated; Retr
172PowercomPowercomExample - Communication address 3:OnOffDIP switchExample - Communication address 4:OnOffDIP switchExample - Communication address 5
173PowercomPowercomSolar-Log™ terminal strip connector Inverter terminal stripTerminal PIN ► 1 ► R+ ► 1 ► T+ ► 4 ► R- ► 4 ► T-4. Close the invert
174Power-One/AuroraPower-One/Aurora60 Power-One/Aurora60�1 Power-One/AuroraEasy Installation Termination Addressing InterfaceYesSwitchYesRS485Overvie
175Power-One/AuroraPower-One/AuroraProcedure1. Open the inverter as shown in the inverter's instructions.2. Connect terminals +T/R, -T/R and RT
176PrimeVOLTPrimeVOLT61 PrimeVOLT61�1 PrimeVOLTEasy Installation Termination Addressing InterfaceNo DIP switch YesRS485Overview•Integrated interfac
177PrimeVOLTPrimeVOLTProcedure1. Open the inverter as shown in the inverter's instructions.2. If you are making the cable yourself, connect the
178PVPoweredPV Powered – central inverter RS48562 PVPowered62�1 PV Powered – central inverter RS485Easy Installation Termination Addressing Interface
179PVPoweredPV Powered – central inverter RS485Connect the inverters to each otherThe wiring is done using a•self-made connection cable and terminal
18Connecting the invertersRJ11 Configuration2 Connecting the invertersAs each inverter manufacturer uses different wiring connections and connectors,
180PVPoweredPV Powered - string inverter62�2 PV Powered - string inverterEasy Installation Termination Addressing InterfaceNo - YesLANOverview•Integ
181Q3Q3 (RS485)63 Q363�1 Q3 (RS485)Easy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated interface•Where to connect:
182Q3Q3 (RS485)Allocate communication address•Recommendation: Continuous numbering starting with 1.•Default settings on the inverter: Communication
183REFUSOLREFUSOL64 REFUSOL64�1 REFUSOLEasy Installation Termination Addressing InterfaceYesTerminating plugYesRS485Overview•Integrated interface•W
184REFUSOLREFUSOLConnect the inverters to each other•Connect using – 2-wire, shielded data cable and – 4-pin "SACC-M12MS-4SC" plug (two
185REFUSOLREFUSOLSet the following parameters on the inverter's operating display:1. Press "F1"2. Select Numerical list, press "E
186REPREP65 REP65�1 REPEasy Installation Termination Addressing InterfaceNo DIP switch YesRS485Overview•Integrated interface•Where to connect: Term
187REPREPProcedure1. Open the inverter as shown in the inverter's instructions.2. If you are making the cable yourself, connect the wires as sh
188ReverberiReverberi (EDI Series)66 Reverberi66�1 Reverberi (EDI Series)Easy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•I
189ReverberiReverberi (EDI Series)Procedure•Open the inverter as shown in the inverter's instructions.•Connect the other inverters to each othe
19Connecting the invertersSwitch off the inverters and Solar-Log™.2�1 Switch o the inverters and Solar-Log™�Switching inverters offAlways turn off a
190RielloRiello67 Riello67�1 RielloEasy Installation Termination Addressing InterfaceNoYesNoRS422Overview•Interface not integrated; Retrofit RS485 i
191RielloRielloProcedure1. Open the inverter as shown in the inverter's instructions.2. Pull the free wires through the wire opening in the inv
192SALICRUSALICRU EQX68 SALICRU68�1 SALICRU EQXEasy Installation Termination Addressing InterfaceNoYesNoRS422Overview•Interface not integrated; Retr
193SALICRUSALICRU EQXProcedure1. Open the inverter as shown in the inverter's instructions.2. Pull the free wires through the wire opening in t
194SALICRUSALICRU EQXLV68�2 SALICRU EQXLVEasy Installation Termination Addressing InterfaceNoResistorYesRS485Overview•Integrated interface•2-pin wi
195Samil PowerSamil Power69 Samil Power69�1 Samil PowerEasy Installation Termination Addressing InterfaceNo - NoRS422Overview•Integrated interface•
196Samil PowerSamil PowerNote:The wiring above refers to the RJ45 or RJ11 socket.3. Insert the RJ1plug into any RJ11 socket on inverter 1.4. Close t
197SanternoSanterno70 Santerno70�1 SanternoEasy Installation Termination Addressing InterfaceNoYesYesRS485Overview•Integrated interface•Where to co
198SanternoSanternoProcedure1. Insert the Santerno inverter data cable plug into socket B of the first inverter.2. Insert the Santerno inverter data
199Schneider ElectricSchneider Electric SunEzy71 Schneider Electric71�1 Schneider Electric SunEzyEasy Installation Termination Addressing InterfaceN
2 Publisher:Solare Datensysteme GmbHFuhrmannstr. 972351 Geislingen-BinsdorfGermanyInternational supportTel.:+49 7428 9418 -640Fax:+49 7428 9418 -280e
20ABBABB PVS3003 ABB3�1 ABB PVS300Easy Installation Termination Addressing InterfaceNo Yes YesRS485Select “ABB-PVS” during the inverter detectionOve
200Schneider ElectricSchneider Electric SunEzyNote Only connect inverter using the RS485/422 B interface.Procedure1. Open the inverter as shown in th
201Schneider ElectricSchneider Electric Xantrex GT30E71�2 Schneider Electric Xantrex GT30EEasy Installation Termination Addressing InterfaceNo - NoSu
202Schneider ElectricSchneider Electric Conext71�3 Schneider Electric ConextEasy Installation Termination Addressing InterfaceNo - YesRS485Overview•
203Schneider ElectricSchneider Electric ConextProcedure1. Open the inverter as shown in the inverter's instructions.2. Insert the RJ45 plug int
204SchücoIPE CN series72 Schüco72�1 IPE CN seriesEasy Installation Termination Addressing InterfaceYesTerminating plugYesRS485 Selectable under RefuS
205SchücoIPE CN series4. Insert the terminal block connector into the Solar-Log™ RS485 socket.Connect the inverters to each other•Connect using – 2
206SchücoIPE CT series72�2 IPE CT seriesEasy Installation Termination Addressing InterfaceNo DIP switch YesRS485 Selectable under Bonfiglioli Overvie
207SchücoIPE CT seriesProcedure1. Get access to the inverter interface2. If you are making the cable yourself, connect the wires as shown in the fol
208SchücoIPE SN series72�3 IPE SN seriesEasy Installation Termination Addressing InterfaceYesYesYesRS485 Selectable under SunwaysOverview•Integrated
209SchücoIPE SN seriesProcedure1. Open the inverter as shown in the inverter‘s instructions.2. Connect terminals RS485+ and RS485- on all inverters
21ABBABB PVS300Procedure1. Unscrew the side cover as shown in the inverter's instructions.2. Connect the self-made RS-485 cable to the X4 termi
210SchücoSchüco SGI series (RS485)72�4 Schüco SGI series (RS485)Easy Installation Termination Addressing InterfaceNoTerminating plugYesRS485 Selectab
211SchücoSchüco SGI series (RS485)Connect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: RJ45 sockets on
212ShindengenShindengen73 Shindengen73�1 ShindengenEasy Installation Termination Addressing InterfaceNo Yes YesRS485 Overview•Integrated interface•
213ShindengenShindengenProcedure1. Open the inverter as shown in the inverter’s instructions.2. If you are fabricating the cable yourself, connect t
214SIELSIEL (single phase)74 SIEL74�1 SIEL (single phase)Easy Installation Termination Addressing InterfaceNoYesYesRS485Overview•Interface not integ
215SIELSIEL (single phase)Example - Communication address 3:OnOffDIP switchExample - Communication address 4:OnOffDIP switchExample - Communication ad
216SIELSIEL (single phase)3. If only one inverter is to be connected terminate this in accordance with the inverter instructions.4. Close the invert
217SiemensSiemens75 Siemens75�1 SiemensEasy Installation Termination Addressing InterfaceYes Resistor YesRS485Overview•Integrated interface•Where t
218SiemensSiemensUse the SACC-M12MS-4SC connectors supplied with the inverter for data cables.•Connect them as shown in the diagram.•Connect the bus
219SiemensSiemensSolar-Log™ compatibility with older PVM installationsWith older Solar-Log™ / PVM installations the inverter had to be set with additi
22ABBABB Central Inverters3�2 ABB Central InvertersEasy Installation Termination Addressing InterfaceNo - YesLANSelect “ABB-PVS” during the inverter
220SMAOverview76 SMA76�1 OverviewSMA inverters do not have an integrated RS485 interface.However, the following RS485 interfaces can be retrofitted t
221SMASMA connection using special RS485 piggyback card76�2 SMA connection using special RS485 piggyback cardEasy Installation Termination Addressing
222SMASMA connection using special RS485 piggyback cardProcedure1. Pull the free wires through the wire opening in the inverter.2. If you are making
223SMASMA connection using special RS485 piggyback cardProcedure1. Pull the wire in the inverter through the insulation sleeve attached to the piggy
224SMAConnect SMA with original SMA RS485 piggy back and the SMA RS485 data module76�3 Connect SMA with original SMA RS485 piggy back and the SMA RS4
225SMAConnect SMA with original SMA RS485 piggy back and the SMA RS485 data module5. Ground the connection: Connect terminal 5 on the inverter to the
226SMASMA Bluetooth mode76�4 SMA Bluetooth modeEasy Installation Termination Addressing InterfaceYesResistor jumperNoRS485Bluetooth mode is only poss
227SMASMA Meter Connection Box76�5 SMA Meter Connection BoxAn energy meter with S0 output can be connected to the SMA Meter Connection Box. The Meter
228SMASMA Speedwire76�6 SMA SpeedwireNoteThe trademark "Speedwire" is registered trademark of SMA Solar Technology AG in many countries.Eas
229SMASMA SpeedwireAssigning IP addresses•A static IP address has to be assigned to the inverter. This is set to automatic by default. Please refer t
23ABBABB-Power-One/Aurora/PVI/TRIO/UNO3�3 ABB-Power-One/Aurora/PVI/TRIO/UNOEasy Installation Termination Addressing InterfaceYesSwitchYesRS485Select
230SOCOMECSOCOMEC Sunsys B20E77 SOCOMEC77�1 SOCOMEC Sunsys B20EEasy Installation Termination Addressing InterfaceNo Yes YesRS485Selection available u
231SOCOMECSOCOMEC Sunsys B20EConnect the inverters to each other•Where to connect: Terminal strip inside the inverter•5-wire cablingProcedure•Open
232SOCOMECSOCOMEC Sunsys B12/B3077�2 SOCOMEC Sunsys B12/B30Easy Installation Termination Addressing InterfaceNoYesYesRS485Selection available under S
233SOCOMECSOCOMEC Sunsys B12/B30Procedure1. Open the inverter according to the inverter‘s instructions.2. Insert the RJ45 plug into the RJ45 socket
234SolarEdgeSolarEdge78 SolarEdge78�1 SolarEdgeEasy Installation Termination Addressing InterfaceNo Switch NoRS485Overview•Integrated interface•Whe
235SolarEdgeSolarEdgeProcedure1. Open the inverter as shown in the inverter's instructions.2. Pull the free wires through the wire opening in t
236SolarMaxSolarMax – S, C, MT, P, TS, TS-SV and HT- series79 SolarMax79�1 SolarMax – S, C, MT, P, TS, TS-SV and HT- seriesEasy Installation Terminat
237SolarMaxSolarMax – S, C, MT, P, TS, TS-SV and HT- seriesCautionRisk of damage to the unit! The Solar-Log™ also has an RJ45 socket, which must never
238SolarMaxSolarMax – S, C, MT, P, TS, TS-SV and HT- seriesConnect the inverters to each other•Connect using the RS485 data cable with an RJ45 plug•
239SolarMax SolarMax – Cx series79�2 SolarMax – Cx seriesEasy Installation Termination Addressing InterfaceYesNoYesRS485Overview•Interface not inte
24ABBABB-Power-One/Aurora/PVI/TRIO/UNOProcedure1. Open the inverter as shown in the inverter’s instructions.2. Connect terminals +T/R, -T/R and RTN
240SolarMax SolarMax – Cx seriesConnect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: RJ45 socket inside
241SolarMax SolarMax – E series79�3 SolarMax – E seriesEasy Installation Termination Addressing InterfaceYesNoYesRS485Overview•Interface not integr
242SolarMax SolarMax – E series3. Run the wire from the Solar-Log™ to inverter 1 through the hole for the wire on the bottom of the unit.4. In the i
243SolarMaxSolarMax via Ethernet interface79�4 SolarMax via Ethernet interfaceEasy Installation Termination Addressing InterfaceNoNoYesLANOverview•I
244SolaX PowerSolaX Power X180 SolaX Power80�1 SolaX Power X1Easy Installation Termination Addressing InterfaceNo Yes AutomaticRS422The following typ
245SolaX PowerSolaX Power X1Procedure1. If you make the cable yourself, connect the wires as shown in the following diagram. Solar-Log™ terminal stri
246SolaX PowerSolaX Power X380�2 SolaX Power X3Easy Installation Termination Addressing InterfaceNo Yes YesRS485The following types are to be connect
247SolaX PowerSolaX Power X3Connect the inverters to each other•Connect using a RJ45 cable.•Where to connect: RJ45 socket.Procedure 1. Insert the s
248SolectriaSolectria >9k81 Solectria81�1 Solectria >9kEasy Installation Termination Addressing InterfaceNo Yes YesRS485The following types ar
249SolectriaSolectria >9kConnect the inverters to each other•Connect with a shielded twisted-pair cable.•Where to connect: Terminal strip inside
25Advanced EnergyAdvanced Energy - AE-14 Advanced Energy4�1 Advanced Energy - AE-1Easy Installation Termination Addressing InterfaceNoSwitchYesRS485
250SolectriaSolectria <9k81�2 Solectria <9kEasy Installation Termination Addressing InterfaceNo Yes NoRS485The following types are to be connec
251SolectriaSolectria <9kConnect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: RJ45 socket (RJ45 R an
252SolutronicSolutronic SP25-55 (RS485)82 Solutronic82�1 Solutronic SP25-55 (RS485)Easy Installation Termination Addressing InterfaceNoYesYesRS485Ove
253SolutronicSolutronic SP25-55 (RS485)Procedure1. Insert the plug into the X2 socket on inverter 1.2. Insert the other end of the wire into the X2
254SolutronicSolutronic SP100, SP120 (RS485)82�2 Solutronic SP100, SP120 (RS485)Easy Installation Termination Addressing InterfaceNoYesYesRS485Overvi
255SolutronicSolutronic SP100, SP120 (RS485)Procedure1. Insert the plug into the X6 socket on inverter 1.2. Insert the other end of the wire into th
256StecaSteca83 Steca83�1 StecaEasy Installation Termination Addressing InterfaceNoSwitchYesRS485Overview•Integrated interface•Where to connect: RJ
257StecaStecaConnect the inverters to each other•Connect using the RS485 data cable with RJ45 plug; Connection cables between the inverters are suppl
258StecaSteca (larger than 17k)83�2 Steca (larger than 17k)Easy Installation Termination Addressing InterfaceNoYesYesRS485Overview•Integrated interf
259StecaSteca (larger than 17k)Connect the inverters to each otherConnect using •a 2-wire shielded data cable and •4-pin Phoenix Contact Connection
26Advanced EnergyAdvanced Energy - AE-1Connect the inverters to each other•Connect using the RS485 data cable with RJ45 plug; Connection cables betwe
260SungrowSungrow84 Sungrow84�1 SungrowEasy Installation Termination Addressing InterfaceYes 120 Ω resistor YesRS485Overview•Integrated interface•W
261SungrowSungrowSolar-Log™ terminal strip connector RJ45 socket inverterTerminal PIN ► 1 ► 6 (Data +A) ► 4 ► 3 (Data -B)2. Insert the plug into th
262SunpowerSunpower SPR-F-Model with Fronius ComCard85 Sunpower85�1 Sunpower SPR-F-Model with Fronius ComCardEasy Installation Termination Addressing
263SunpowerSunpower SPR-F-Model with Fronius ComCardProcedure1. If you are making the cable yourself, connect the wires as shown in the following dia
264SunpowerSunpower SPR-M-Model connection using special RS485 piggyback card85�2 Sunpower SPR-M-Model connection using special RS485 piggyback cardE
265SunpowerSunpower SPR-M-Model connection using special RS485 piggyback cardProcedure1. Pull the free wires through the wire opening in the inverter
266SunpowerSunpower SPR-M-Model connect with original SMA RS485 piggy back and the SMARS485 data module85�3 Sunpower SPR-M-Model connect with origina
267SunpowerSunpower SPR-M-Model connect with original SMA RS485 piggy back and the SMARS485 data moduleSolar-Log™ terminal strip connector Inverter te
268SunpowerSunpower SPR-M-Model connect with original SMA RS485 piggy back and the SMARS485 data moduleProcedure1. Pull the wire in the inverter thro
269SuntechnicsSuntechnics (only Solar-Log 1000 and 2000)86 Suntechnics86�1 Suntechnics (only Solar-Log 1000 and 2000)Note Suntechnics inverters can o
27Advanced EnergyAdvanced Energy - AE-34�2 Advanced Energy - AE-3Easy Installation Termination Addressing InterfaceYesTerminating plugYesRS485Select
270SuntechnicsSuntechnics (only Solar-Log 1000 and 2000)Connecting inverters to each other (only Solar-Log1000 and 2000)•Connection is made only with
271SuntiguaSuntigua87 Suntigua87�1 SuntiguaEasy Installation Termination Addressing InterfaceNo DIP switch YesRS485Overview•Integrated interface•Wh
272SuntiguaSuntiguaProcedure1. Open the inverter as shown in the inverter's instructions.2. If you are making the cable yourself, connect the w
273SunvilleSunville88 Sunville88�1 SunvilleEasy Installation Termination Addressing InterfaceYesYesNoRS422Overview•Interface not integrated; Retrofi
274SunvilleSunvilleProcedure1. Open the inverter as shown in the inverter's instructions.2. Pull the free wires through the wire opening in the
275SunwaysSunways - AT/NT/PT 89 Sunways89�1 Sunways - AT/NT/PT Easy Installation Termination Addressing InterfaceYesYesYesRS485Overview•Integrated i
276SunwaysSunways - AT/NT/PT Connect the inverters to each other•Connect using a 2 wire, shielded data cable•Where to connect: Terminal strip inside
277Sustainable EnergySustainable Energy90 Sustainable Energy90�1 Sustainable EnergyEasy Installation Termination Addressing InterfaceNo Terminating p
278Sustainable EnergySustainable EnergyProcedure1. Connect terminal 2 (A out) on inverter 1 to terminal 4 (A in) on inverter 2.2. Connect terminal 1
279TBEATBEA91 TBEA91�1 TBEAEasy Installation Termination Addressing InterfaceNo 120 Ω resistor YesRS485Overview•Integrated interface•Where to conne
28Advanced EnergyAdvanced Energy - AE-3On the sockets „RS485 OUT“ with REFUSOL round plugs bypass the connections PIN1 to PIN2 and PIN3 to PIN4.6. Cl
280TBEATBEAProcedure1. Insert the round plug into the COM round socket 1 on inverter 12. Connect additional inverters to each other according to the
281TrannergyTrannergy92 Trannergy92�1 TrannergyEasy Installation Termination Addressing InterfaceNo Yes NoRS485Overview•Interface not integrated; Re
282TrannergyTrannergyNoteOnly connect inverter using the RS485/422 B/C interface.Procedure1. Open the inverter as shown in the inverter's instru
283VaillantVaillant – auroPOWER VPI /1 and VPI (RS485)93 Vaillant93�1 Vaillant – auroPOWER VPI /1 and VPI (RS485)Easy Installation Termination Addres
284VaillantVaillant – auroPOWER VPI /1 and VPI (RS485)Connect the inverters to each other•Connect using a 2 wire, shielded data cable•Where to conne
285ValeniaValenia94 Valenia94�1 ValeniaEasy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated interface•Where to conn
286ValeniaValeniaConnect the inverters to each otherThe wiring is done using a•self-made connection cable and terminal block connector.•Where to con
287Varta Engion Battery SystemVarta Engion Battery System95 Varta Engion Battery System95�1 Varta Engion Battery SystemEasy Installation Termination
288Varta Engion Battery SystemVarta Engion Battery SystemConnect the consumption meter to the Solar-Log™�The wiring is done using a•RS485 or•S0 inte
289VectronVectron96 Vectron96�1 VectronInverters manufactured by Bonfiglioli Vectron GmbH were listed under „Vectron“ up to firmware version 3.1.2.
29Advanced EnergyAdvanced Energy - AE-TX4�3 Advanced Energy - AE-TXEasy Installation Termination Addressing InterfaceNo Jumper YesRS485Select “PVPowe
290VisionVision Multitracker97 Vision97�1 Vision MultitrackerEasy Installation Termination Addressing InterfaceNoDIP switchYesRS485Select “Vision” du
291VisionVision MultitrackerProcedure1. If you are fabricating the cable yourself, connect the wires as shown in the following diagram.Solar-Log™ ter
292VisionVision Singletracker97�2 Vision SingletrackerEasy Installation Termination Addressing InterfaceNoDIP switchYesRS485Select “Vision SM” during
293VisionVision SingletrackerProcedure1. If you are fabricating the cable yourself, connect the wires as shown in the following diagram.Solar-Log™ te
294VoltwerkVoltwerk (only Solar-Log 1000 and 2000)98 Voltwerk98�1 Voltwerk (only Solar-Log 1000 and 2000)Note Voltwerk inverters can only be connecte
295VoltwerkVoltwerk (only Solar-Log 1000 and 2000)Connecting inverters to each other (only Solar-Log 1000 and 2000)•Connection is made only with a re
296WINAICOWINAICO99 WINAICO99�1 WINAICOEasy Installation Termination Addressing InterfaceNoSwitchYesRS485•Interface not integrated; Retrofit RS485 i
297WINAICOWINAICOExample - Communication address 3:OnOffDIP switchExample - Communication address 4:OnOffDIP switchExample - Communication address 5:O
298WINAICOWINAICOSolar-Log™ terminal strip connector Inverter terminal stripTerminal Terminal ► 1 ► R+ ► 4 ► R- ► 5 ► T+ ► 6 ► T-4. If only one i
299WürthWürth SolarStar-Series100 Würth100�1 Würth SolarStar-SeriesEasy Installation Termination Addressing InterfaceYesNoYesRS485Select “SolarMax” d
3 Table of Contents1 Connections �������������������������������������������������������������������������������������������������������������������1
30Advanced EnergyAdvanced Energy - AE-TXProcedure1. Open the inverter as shown in the inverter‘s instructions.2. Pull the free wires through the wir
300WürthWürth SolarStar-SeriesProcedure1. If you are making the cable yourself, connect the wires as shown in the following diagram:Solar-Log™ termin
301YaskawaYaskawa101 Yaskawa101�1 YaskawaEasy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated interface•Where to co
302YaskawaYaskawaConnect the inverters to each otherThe inverters are connected together using the RS485 interface. Refer to the manufacturer's i
303Zentral Solar Deutschland ZSDZentral Solar Deutschland ZSD (RS485)102 Zentral Solar Deutschland ZSD102�1 Zentral Solar Deutschland ZSD (RS485)Easy
304Zentral Solar Deutschland ZSDZentral Solar Deutschland ZSD (RS485)Connect the inverters to each other•Connect using a network cable (patch cable)•
305Zentral Solar Deutschland ZSDZentral Solar Deutschland ZSD - zentralpower102�2 Zentral Solar Deutschland ZSD - zentralpowerEasy Installation Termin
306ZeversolarZeversolar103 Zeversolar103�1 ZeversolarEasy Installation Termination Addressing InterfaceNoYesNoRS422Overview•Interface integrated.•W
307ZeversolarZeversolarProcedure1. If you are making the cable yourself, connect the wires as shown in the following diagram:Solar-Log™ terminal stri
308AppendixSMA mixed wiring104 Appendix104�1 SMA mixed wiringFigure 16: SMA mixed wiring
309AppendixInterconnection of Kaco Powador inverters104�2 Interconnection of Kaco Powador invertersFigure 17: Interconnection of Kaco Powador inverter
31AEGAEG PS5 AEG5�1 AEG PSEasy Installation Termination Addressing InterfaceNoYesNoRS422Select “AEG-PS” during the inverter detectionOverview•Inter
310List of figuresInterconnection of Kaco Powador inverters105 List of figuresFigure 1: RJ45 plug pin assignments ...
The copyright of these instructions remains with the manufacturer. No part of these instructions may be may be reproduced in any form or processed, du
32AEGAEG PSNoteOnly connect inverter using the RS485/422 B/C interface.Procedure1. Open the inverter as shown in the inverter's instructions.2.
33AEGAEG Protect5�2 AEG ProtectEasy Installation Termination Addressing InterfaceNo Terminating plug nenRS485Select “AEG-Protect” during the inverter
34AEGAEG ProtectConnect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: 2 RJ45 sockets on the right on the
35AlbatechAlbatech APL Trifase 15 / 206 Albatech6�1 Albatech APL Trifase 15 / 20Easy Installation Termination Addressing InterfaceNo Jumper YesRS485
36AlbatechAlbatech APL Trifase 15 / 20Procedure1. Switch off the inverters and Solar-Log™2. Unscrew the side cover as shown in the inverter‘s instru
37AlbatechAlbatech APL Monofase6�2 Albatech APL MonofaseEasy Installation Termination Addressing InterfaceNo Jumper YesRS485APL Monofase 2�0/3�0/4�0/
38AlbatechAlbatech APL MonofaseConnect the inverters to each other•Connect using a 3 wire, shielded data cable•Where to connect: on the upgraded RS4
39ALPHA-SOLALPHA-SOL7 ALPHA-SOL7�1 ALPHA-SOLEasy Installation Termination Addressing InterfaceNoSwitchYesRS485Overview•Interface not integrated; Re
4 8�2 AROS Solar Technology (RS485) ����������������������������������������������������������������������������������������������������������������
40ALPHA-SOLALPHA-SOLExample - Communication address 3:OnOffDIP switchExample - Communication address 4:OnOffDIP switchExample - Communication address
41ALPHA-SOLALPHA-SOLSolar-Log™ terminal strip connector Inverter terminal stripTerminal Terminal ► 1 ► R+ ► 1 ► T+ ► 4 ► R- ► 4 ► T-4. If only on
42AROS Solar TechnologyAROS Solar Technology (RS422)8 AROS Solar Technology8�1 AROS Solar Technology (RS422)Easy Installation Termination Addressing
43AROS Solar TechnologyAROS Solar Technology (RS422) Note Only connect inverter using the RS485/422 B /C interface� Procedure1. If you are making the
44AROS Solar TechnologyAROS Solar Technology (RS485)8�2 AROS Solar Technology (RS485)Easy Installation Termination Addressing InterfaceNo Yes NoRS485
45AROS Solar TechnologyAROS Solar Technology (RS485)Procedure1. Open the inverter as shown in the inverter's instructions.2. Connect terminals
46AstronergyAstronergy9 Astronergy9�1 AstronergyEasy Installation Termination Addressing InterfaceNo - YesRS485Select „Astronergy“ during the invert
47AstronergyAstronergyAllocate communication address•Recommendation: Continuous numbering starting with 1.•Address range: 1 - 125 •Setting: Using t
48AtenAten10 Aten10�1 AtenEasy Installation Termination Addressing InterfaceNo - NoRS485Overview•Integrated interface•Where to connect: RJ14 socket
49AtenAtenConnect the inverters to each other•Connect using a 2 wire, shielded data cable•Where to connect: RJ14 sockets.Procedure 1. Open the inve
5 18 Danfoss ���������������������������������������������������������������������������������������������������������������������������7018�1 Danfos
50BenningBenning11 Benning11�1 BenningEasy Installation Termination Addressing InterfaceNoNoYesLANOverview•Integrated interface•The inverter'
51BenningBenningDetection from the Solar-Log™•For the detection on the Solar-Log™ , select "Benning" as the inverter manufacturer in the Co
52Bonfiglioli (formerly Vectron)Bonfiglioli12 Bonfiglioli (formerly Vectron)12�1 BonfiglioliEasy Installation Termination Addressing InterfaceNo DIP s
53Bonfiglioli (formerly Vectron)BonfiglioliConnect the inverters to each other•Where to connect: Terminal strip on the inverter•3-pin wiringProcedur
54Carlo GavazziCarlo Gavazzi - ISMG model13 Carlo Gavazzi13�1 Carlo Gavazzi - ISMG modelEasy Installation Termination Addressing InterfaceNo - NoRS4
55Carlo GavazziCarlo Gavazzi - ISMG modelConnect the inverters to each other•Connect using a network cable (patch cable)•Where to connect: RJ45 sock
56Carlo GavazziCarlo Gavazzi - HINRG model13�2 Carlo Gavazzi - HINRG modelEasy Installation Termination Addressing InterfaceNo DIP switch YesRS485 Se
57Carlo GavazziCarlo Gavazzi - HINRG modelProcedure1. Open the inverter as shown in the inverter's instructions.2. If you are making the cable
58Chint PowerChint Power (CSP SC and CSP SCE to 20k)14 Chint Power14�1 Chint Power (CSP SC and CSP SCE to 20k)Easy Installation Termination Addressin
59Chint PowerChint Power (CSP SC and CSP SCE to 20k)ProcedureCautionRisk of damage to the unit! The Solar-Log™ also has an RJ45 socket, which must nev
6 27�2 Eltek central inverter ����������������������������������������������������������������������������������������������������������������������
60Chint PowerChint Power (CPS 20k+)14�2 Chint Power (CPS 20k+)Easy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated i
61Chint PowerChint Power (CPS 20k+)Procedure1. Insert the RJ45 plug into any RJ45 socket on inverter 1.2. Insert the other end of the wire into any
62Chint PowerChint Power Modbus14�3 Chint Power ModbusEasy Installation Termination Addressing InterfaceNo No YesRS485The following types are to be c
63Chint PowerChint Power ModbusProcedure1. If you are making the cable yourself, connect the wires as shown in the following diagram:Solar-Log™ termi
64CMSCMS15 CMS15�1 CMSEasy Installation Termination Addressing InterfaceNo DIP switch YesRS485Overview•Integrated interface•Where to connect: Term
65CMSCMSProcedure1. Open the inverter as shown in the inverter's instructions.2. If you are making the cable yourself, connect the wires as sho
66ConergyConergy (only Solar-Log 1000 and 2000)16 Conergy16�1 Conergy (only Solar-Log 1000 and 2000)Note Conergy inverters can only be connected to t
67ConergyConergy (only Solar-Log 1000 and 2000)Connecting inverters to each other (only Solar-Log1000 and 2000)•Connection is made only with a ready-
68CyberPowerCyberPower17 CyberPower17�1 CyberPowerEasy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated RS485 interf
69CyberPowerCyberPowerConnect the inverters to each other•Connect using a network cable (patch cable).•Where to connect: RJ45 socket on the outside
7 37 Growatt�������������������������������������������������������������������������������������������������������������������������� 11837�1 Growat
70DanfossDanfoss18 Danfoss18�1 DanfossEasy Installation Termination Addressing InterfaceYesConnection plugNoRS485Overview•Integrated interface•Whe
71DanfossDanfoss3. If only one inverter is to be connected this must be terminated. Insert the supplied connection plug into any free RJ45 socket on
72DeltaDelta (RS485)19 Delta19�1 Delta (RS485)Easy Installation Termination Addressing InterfaceYesResistorYesRS485Overview•Integrated interface•Wh
73DeltaDelta (RS485)2. Insert the RJ45 plug into the RJ45 socket on the inverter.3. If only one inverter is connected this must be terminated. Inser
74Diehl AkoDiehl Ako20 Diehl Ako20�1 Diehl AkoDiehl Ako inverters have been listed as „Diehl Ako“ in our firmware up to version 3.1.1. Starting with
75EatonEaton21 Eaton21�1 EatonEasy Installation Termination Addressing InterfaceNoYesNoRS422Overview•Interface not integrated; Retrofit RS485 inter
76EatonEatonNoteOnly connect inverter using the RS485/422 B/C interface.Procedure1. Open the inverter as shown in the inverter's instructions.2.
77EEIEEI22 EEI22�1 EEIEasy Installation Termination Addressing InterfaceNoNoYesLANOverview•Integrated interface•The inverter‘s IP address has to be
78EffektaEffekta23 Eekta23�1 EektaEasy Installation Termination Addressing InterfaceNoJumperYesRS485Select "Effekta ES" during the invert
79EffektaEffekta3. If only one inverter is to be connected this must be terminated. Set the jumper on the RS485 interface card to ON.4. Close the in
8 47 Kyocera Inverter/Battery System �����������������������������������������������������������������������14647�1 Kyocera Inverter/Battery System
80EffektaEffekta KS Multitracker23�2 Eekta KS MultitrackerEasy Installation Termination Addressing InterfaceNoDIP switchYesRS485Select “Effekta KS”
81EffektaEffekta KS MultitrackerProcedure1. If you are fabricating the cable yourself, connect the wires as shown in the following diagram.Solar-Log™
82EffektaEffekta KS Singletracker23�3 Eekta KS SingletrackerEasy Installation Termination Addressing InterfaceNoDIP switchYesRS485Select “Effekta KS
83EffektaEffekta KS SingletrackerProcedure1. If you are fabricating the cable yourself, connect the wires as shown in the following diagram.Solar-Log
84EnfinityEnfinity24 Enfinity24�1 EnfinityEasy Installation Termination Addressing InterfaceNo - YesRS422Overview•Integrated interface•2 RJ11 sockets
85EnfinityEnfinityConnect the inverters to each other•Wiring using the RJ11 cable•Where to connect: RJ11 socketsProcedure 1. Open the inverter as s
86EHEEHE N1k5TL to N50kTL25 EHEEhe offers three wiring options for their various models. Some models can be connected using a bus. Please note that th
87EHEEHE N1k5TL to N50kTLProcedure•If you are making the cable yourself, connect the wires as shown in the following diagram:Solar-Log™ terminal stri
88EHEEHE N10k to N100k25�2 EHE N10k to N100kEasy Installation Termination Addressing InterfaceNo Yes YesRS485The following types are to be connected
89EHEEHE N10k to N100kConnect the inverters to each other•Connect with a shielded twisted-pair cable.•Where to connect: Terminal strip inside the in
9 57�1 PhonoCube 7�2 (Battery Hybrid System) �������������������������������������������������������������������������������������������������������
90EHEEHE N250k to N500k-TL25�3 EHE N250k to N500k-TLEasy Installation Termination Addressing InterfaceNo Yes YesRS485The following types are to be co
91EHEEHE N250k to N500k-TLProcedure•If you make the cable yourself, connect the wires as shown in the diagram: Terminal strip inside the first inverte
92EKO EnergyEKO Energy26 EKO Energy26�1 EKO EnergyEasy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated interface•Wh
93EKO EnergyEKO EnergyProcedure1. Insert the round plug into any round socket on inverter 1.2. Insert the other end of the cable into any round sock
94EltekEltek27 Eltek27�1 EltekEasy Installation Termination Addressing InterfaceNo Yes YesRS485Overview•Integrated interface•Where to connect: Term
95EltekEltekOther configurations•Activate the RS485 interface Using the inverter operating display.NotePay particular attention to the instructions i
96EltekEltek central inverter 27�2 Eltek central inverter Easy Installation Termination Addressing InterfaceNo DIP switch YesRS485Select "Eltek
97EltekEltek central inverter Other configurations•Activate the RS485 interface Using the inverter operating display.NoteAddress settings: from inver
98Europa-Solar AGEuropa-Solar AG28 Europa-Solar AG28�1 Europa-Solar AGEasy Installation Termination Addressing InterfaceNoYesNoRS422Overview•Integra
99Europa-Solar AGEuropa-Solar AGSolar-Log™ terminal strip connector RJ45 inverterTerminal PIN ► 1 ► Pin 3 ► 4 ► Pin 6 ► 5 ► Pin 1 ► 6 ► Pin 23. I